3G GSM Gate and Garage Door Opener Controller UAE
Mobile Phone Access for Automatic EntrancesThis cellular gate controller adds mobile-call access to ..
Find NICE spare parts for gate, garage door and shutter automation: control boards, remotes, receivers, photocells, batteries and mechanical parts. Send your model number and we will confirm the match.
Compare available models and open a product for its specifications and compatibility details.
Mobile Phone Access for Automatic EntrancesThis cellular gate controller adds mobile-call access to ..
ROA6 Sliding Gate Rack: Product OverviewNICE ROA6 is a reinforced nylon rack for compatible sliding ..
ROA7 Sliding Gate Rack: Product OverviewNICE ROA7 is a 22 × 22 × 1000 mm galvanised steel M4 rack fo..
ROA8 Sliding Gate Rack: Product OverviewNICE ROA8 is a galvanised steel M4 gear rack supplied with s..
ROA81 Sliding Gate Rack: Product OverviewNICE ROA81 is a galvanised steel Module 6 rack measuring 30..
Vehicle Presence Detection for Gates and Parking BarriersThe PD-132 is a single-channel inductive de..
Smartphone Control for Your Existing Garage DoorAdd convenient phone access to a compatible powered ..
Mobile Phone Access for Automatic EntrancesWH-120 PRO 4G is a cellular access controller that lets a..
NICE EPM Outdoor Infrared Gate Safety Photocells UAEThe NICE EPM Era Photocell Sensors are a genuine..
NICE EPMB Two-Wire BlueBUS Gate Safety Photocells UAEThe NICE EPMB Era BlueBUS Photocell Sensors are..
NICE EDSWG 433.92 MHz Wireless Access Keypad UAEThe NICE ERA EDSWG Wireless Keypad is a genuine NICE..
NICE BusT4 Smartphone Gate & Garage Door Controller UAEThe NICE IT4WIFI Wi-Fi Interface is a genuine..
NICE ELDC 12–36 V Gate Flashing Light with Integrated AerialThe NICE ERA ELDC LED Flashing Light is ..
NICE ELAC 90–240 VAC Warning Light with Integrated AerialThe NICE ERA ELAC LED Flashing Light is a g..
NICE OXIBD Plug-In Radio Receiver for Gate AutomationThe NICE OXIBD Bidirectional Radio Receiver is ..
NICE OXIFM 4-Channel O-Code Gate Receiver for Opera SystemsThe NICE OXIFM Radio Receiver is a genuin..
NICE OX2 2-Channel Pre-Wired Radio Receiver UAEThe NICE OX2 Universal Radio Receiver is a genuine NI..
Replacement Release Lock for Compatible NICE ROBUS & RUN MotorsThe NICE Sliding Gate Motor Manual Re..
Original NICE RBA3 Replacement Control Unit with BlueBUSThe NICE RBA3 Control Board is an original r..
NICE RBA3/C Replacement PCB for RB400 RB600 & RB1000The NICE RBA3/C Control Board is an original rep..
NICE WIA20 R10 Replacement PCB for WIDE S, M & L BarriersThe NICE SPWIA20R10 Control Board, also ide..
NICE RUA1 Replacement PCB for RUN1800 and RUN2500 MotorsThe NICE RUA1 Control Board is an original r..
Original NICE ROA40 Replacement Control Unit for ROX600The NICE ROA40 Control Board is an original r..
Original NICE ROA37 Replacement PCB for TH1500The NICE ROA37 Control Board is an original replacemen..
NICE MC800 BlueBUS Control Panel for 1 or 2 Swing Gate MotorsThe NICE MC800 Control Unit is an origi..
NICE gate motor spare parts help repair, maintain and extend the service life of compatible sliding gate, swing gate, garage door and rolling shutter installations. Replacement components must match the exact motor generation, control board code, accessory interface and electrical requirements.
Explore NICE controllers, photocell sensors, radio receivers, keypads and related automation accessories for villas, residential communities, commercial buildings and industrial entrances across the UAE.
Use the manufacturer part number and installed control system to identify spare parts; visually similar components are not always electrically interchangeable.
NICE replacement PCBs manage motor movement, accessory inputs, limit information and, on certain models, radio functions. Examples in the imported catalogue include RBA3 and RBA3/C for specific ROBUS generations, ROA40 for a corresponding ROX family, ROA37 for THOR, RUA-series boards for RUN, MC800 and MC824H for selected swing systems, and other application-specific control units. A PCB that looks physically similar may use different firmware, connectors, supply voltage or safety wiring. Read the exact part number on the installed board, confirm the motor model and generation, and compare the terminal map before replacement. Programming and safety validation should be repeated after a control-unit change; blindly swapping boards can damage components or leave a gate operating unsafely.
NICE photocells detect an interruption of the beam across a gate or door passage and are used as part of a designed safety system. The EPM and EPMB references are not identical replacement choices. In particular, EPMB is associated with NICE BlueBUS-compatible wiring, while the exact interface on a given EPM version must be checked against the installed controller. A safety sensor should be chosen based on the approved control-board input, mounting geometry, environmental exposure and required risk-reduction function. Following installation, the sender and receiver must be aligned and the protective response verified over the full movement cycle. A photocell alone does not remove the need for mechanical stops or additional safety measures where the risk assessment requires them.
NICE radio receivers and access devices enable authorised commands from compatible remote transmitters, keypads and other controls. Catalogue references include receiver families such as OXIBD, OXIFM and OX2, plus ERA-series keypads and external key selectors. These components cannot be assumed interchangeable because their receiver form factor, operating frequency, encoding and electrical interfaces may differ. Before ordering, check whether the controller provides a plug-in receiver socket or expects a dry-contact external receiver. Also identify the transmitter family to be enrolled and the administrator’s required procedure for managing user access. Access-control additions should be wired so that gate safety functions remain operative regardless of how an opening command is generated.
Mechanical and auxiliary gate-automation parts include rack sections, release keys and lock cylinders, mounting brackets, flashing indicators, antenna accessories and controller enclosures. For a failed component, first determine whether the fault is mechanical, electrical or related to programming. Replacement release cylinders must match the actual motor housing; rack dimensions and tooth form must suit the installed pinion; and flashing lamps must have the correct supply and wiring arrangement. Selecting a matching NICE part number is particularly important for equipment that has changed generations. After any replacement, complete functional testing, manual-release checks and safety verification before putting the entrance back into service.
Photograph the motor identification label, existing part number, board connectors and terminal layout. Describe the fault and whether the gate moves manually, receives remote commands, or displays an error. Identify the full model generation rather than relying only on a family name.
Confirm the replacement component’s supported supply, wiring, radio technology and control-board revision. Safety devices must be tested after repair, and electrical troubleshooting should be carried out by appropriately qualified personnel. Replacing a PCB without addressing mechanical or wiring faults can lead to repeated failure.
Ask for Technical GuidanceCompatible parts may include controller boards, photocells, BlueBUS modules, receivers, antennas, remotes, flashing lights, keypads, release assemblies and sliding gate gear racks. Check each accessory against the original model documentation before purchasing or installation.
We handle NICE spare-part inquiries for customers in Dubai, Sharjah, Abu Dhabi, Ajman, Ras Al Khaimah, Umm Al Quwain, Fujairah and Al Ain. Provide the installed motor and component model numbers for assistance identifying compatible replacement products.
The most reliable starting point is the complete model number of the original gate or door motor and the printed code on the component being replaced. NICE electronics can change between generations even when the product family name remains the same. PCB form, connector location or casing shape is not proof of interchangeability.
Photograph the whole motor label, both sides of a circuit board where safe, any part number sticker and the visible connector positions. For mechanical parts such as gears, racks and release mechanisms, confirm dimensions and the exact compatible drive system.
Control units manage motor direction, speed or torque settings, accessory inputs, limit recognition, receiver memory and safety logic. Families such as RBA, ROA, RUA and MC may correspond to different automation systems. Certain spare boards require compatible firmware, accessories or commissioning steps.
Before ordering, verify the complete PCB part reference and motor nameplate. Substituting a control unit intended for another motor generation can result in malfunction or unsafe operation, even where plug connectors appear similar.
Photocells detect interrupted beams or other relevant hazards, but the connection method differs by device. Conventional relay-contact photocells are not the same as NICE BlueBUS units, which require compatible controller communications. Some installations also need additional safety equipment based on the risk assessment.
Check voltage, output type, supported wiring distance, mounting alignment and the environment. Photocells that are wet, misaligned or obstructed can produce intermittent failures; simply bypassing safety devices is not an appropriate repair.
Receiver modules determine which transmitters a gate system can accept. The correct match depends on frequency, coding family, plug-in or external interface, and programming support. An external receiver may sometimes offer a migration path for older systems, provided the motor controller supports the required command input.
Antenna condition and position also affect operation range. When diagnosing intermittent remote performance, check receiver power, antenna wiring and nearby sources of interference before replacing the entire motor.
Flashing indicators, warning devices, release assemblies and gear racks must be selected according to the specific motor and installation. A sliding gate rack needs the correct tooth pitch, mounting height and length for the full travel. Mechanical end stops must remain functional after replacement work.
For a flashing lamp or electrical lock, verify operating voltage, power consumption and control-board output limits. Incorrect accessories can damage outputs or produce unreliable operation.
Start by documenting the fault: whether the motor hums, moves briefly, stops in one direction, loses radio range or displays a controller error. Check the gate mechanism and external safety inputs before assuming the PCB is defective.
Qualified technicians should isolate power before opening electrical enclosures. Replacement components should be commissioned with a complete safety test, including obstacle and release functions where applicable.
Check the full motor nameplate, existing PCB part number and version. Boards for different generations may require different wiring or programming.
No. BlueBUS sensors require a supported controller and compatible connection method.
No. The receiver must support the remote frequency and coding family.
Provide clear photos of the motor label, component label and connectors, along with a description of the required repair.
No. Match the exact ROBUS motor generation and supported PCB reference; different models and variants can use different electronics.
Not universally. Their connection types and supported controllers can differ, including conventional versus BlueBUS arrangements.
The existing part number, full motor code, clear images of the component and connectors, and a brief fault description.